If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
Interlock Switches Non contact Switches Sipha Control Units Specifications (continued) Safety Inputs Sipha 1 1 N.C. & 1 N.O. Sipha 2 & 6 6 x (1 N.C. & 1 N.O.) Maximum Input Resistance Terminals 1 - 4 200 Terminals 2 - 3 150 Minimum Approach Speed Safety Outputs Sipha 1 1 N.O. Sipha 1 2 N.O. Sipha 6 2 N.O. + 1 N.O. Delayed (0.6 to 30sec) Output Rating Minimum Switched Current/ Voltage Maximum Recommended Output Fuse B300, AC-15, 4A/250V AC P300, DC-15, 2A/30V DC 10mA/10V 5A quick blow AC, 3A quick blow DC 17mm/s (0.67in/s) Description With the increasing speed and complexity of applications a simple magnetic switch may be insufficient to meet the increased risks, therefore Sipha's design incorporates several magnetically sensitive elements which must be triggered in a particular sequence to operate correctly. The Sipha sensor, designed to operate with its own actuator, helps prevent defeatability by a simple magnet. The control unit is available in three types. The Sipha 1 control unit operates on 24V AC/DC and offers 1 N.O. safety output and 1 N.C. solid state auxiliary output. The Sipha 2 control unit operates on either 24V AC/DC, 110V AC or 230V AC and offers 2 N.O. safety outputs and 1 N.C. auxiliary output. The Sipha 6 has wiring terminals for up to 6 sensors, a delayed output for Category 1 stops and offers the same wide range of power supply capability as the Sipha 2 control unit. Between 2 and 6 Sipha sensors can be directly connected to the Sipha 6 control unit. An internal DIP switch mutes the unused connections to sensors 1, 2, 3 and 4. This allows for individual monitoring to each interlock and provides enhanced safety integrity when compared to six interlocks running off a single Sipha 2 control unit. The Sipha control units are designed to operate with the Sipha sensors and actuators. The controllers have automatic reset. Auxiliary Outputs (not for safety use) Sipha 1 1 N.C. Photovoltaic MOSFET (on resistance typically 36) Sipha 2 & 6 1 N.C. Auxiliary Output Switching Capability Sipha 1 100mA/230V AC, 100mA/24V DC Sipha 2 & 6 2A/230 V AC, 2A/24 V DC Indication LEDs Impulse Withstand Voltage Installation Group Pollution Degree Operating Temperature Humidity Torque Settings-- Terminal Screws Conductor Size Case Material Mounting Weight Sipha 1 140g (0.31lbs) Sipha 2 410g (0.90lbs) Sipha 6 675g (1.49lbs) Electrical Life 220V AC/4A880VA cos=.35 220V AC/1.7A375VA/ cos=.6 30V DC/2A60W 10V DC/0.01A/0.1W Mechanical Life Vibration Shock 100,000 operations 500,000 operations 1,000,000 operations 2,000,000 operations 2,000,000 operations 1mm, 10 to 55Hz 30g, 11ms half-sine Green LED = Power on Green LED = Output closed 2500V C in accordance with VDE 0110 3 -10C to +55C (+14 to +131F) 90% RH 1Nm (8.85lbin) 0.2-2.5mm2 (24-14AWG) Red Polycarbonate 35mm DIN Rail Features * * * * Non contact actuation Magnetic coded sensing Control Unit acts as safety relay Four types of switches Specifications Standards EN954-1, ISO13849-1, IEC/EN60204-1, NFPA79, EN1088, ISO14119, IEC60947-5-1, ANSI B11.19, AS4024.1 Sipha 1 & 2 Cat. 3 per EN954-1 Sipha 6 Cat. 4 per EN954-1 Approvals Power Supply Sipha 1 24V AC/DC Sipha 2 & 6 24V AC/DC and 110/230V AC Power Consumption Sipha 1 <2VA Sipha 2 & 6 <4VA CE marked for all applicable directives, cULus and TUV Category 3-56 Interlock Switches Non contact Switches Sipha Control Units Product Selection Housing Supply Voltage Safety Contacts Auxiliary Contacts Housing Type Catalogue Number 24V AC/DC 1 N.O. 1 N.C. Solid State 22.5mm Control Unit 1 440N-S32013 24V AC/DC 110V/230V AC 2 N.O. 1 N.C. 45mm Control Unit 2 440N-S32021 24V AC/DC 110/230V AC 2 N.O. 1 N.O. Delayed 1 N.C. 90mm Sipha 6 440N-S32052 Accessories Housing Replacement Fuse, 500mA Page Number 14-6 Catalogue Number 440R-A31562 Approximate Dimensions--mm (inches) Dimensions are not intended to be used for installation purposes. Sipha Control Unit Type 1 22.5 (0.89) 99 (3.9) 120 (4.72) 45.5 (1.79) Sipha Control Unit Type 2 82 (3.23) 75 (2.95) 35mm DIN Rail Mounting 35mm DIN Rail Mounting Sipha 6 Control Unit 76 (2.99) 83 (3.27) 118 (4.65) 84 (3.31) 90 (3.54) 73 (2.87) 3-57 Interlock Switches Non contact Switches Sipha Control Units Block Diagrams Sipha 1 Sipha 1 L F1 N +Ve F2 K1 K1 K2 K1 X1 X2 13 23 21 A1 A2 K1 X1 X2 13 21 ~ K2 K1 110/230 24V DC Pwr Out Logic K1 K2 K2 ~ Pwr Out K1 K2 K2 Logic NC -Ve 1 2 3 4 14 24 22 2 1 3 4 14 22 Typical Wiring Diagrams 24V AC/DC Blue Sipha Actuator Sipha Sensor Yellow L1 L2 L3 2 1 A1 13 21 X1 K1 Guard Closed Sipha 1 Control Unit Reset K2 22 X2 3 4 A2 14 Green Red K1 K2 Aux to Indicator or PLC Input M Single Sipha Sensor, 24V Supply, Dual Channel Output, Manual Reset, Monitored Output 110V AC L1 Blue Sipha Actuator Sipha Sensor Yellow L1 L2 L3 2 1 A1 Sipha 2 Control Unit 13 23 31 X1 K1 Guard Closed 110V 230V 3 4 Reset K2 A2 14 24 32 X2 Green Red K1 K2 N Aux to Indicator or PLC Input M Single Sipha Sensor, 110V AC Supply, Dual Channel Output, Manual Reset, Monitored Output 3-58 Interlock Switches Non contact Switches Sipha Control Units Typical Wiring Diagrams (continued) 24V AC/DC Blue Sipha Actuator Sipha Sensor Yellow L1 L2 L3 2 Black White Guard Closed 1 A1 Sipha 2 Control Unit 13 23 31 X1 K1 Aux contact for indication Blue Reset K2 3 4 A2 Sipha Actuator 14 24 32 X2 Sipha Sensor Red Yellow White Guard Closed Aux contact for indication Blue Sipha Actuator Sipha Sensor Red Guard Closed Aux contact for indication Multiple Sipha Sensor, Manual Reset, Dual Channel Output, Monitored Output Application Details See page 3-62 for application details. White Black Green K1 K2 Black Aux to Indicator or PLC Input M 3-59 |
Price & Availability of 440N-S32013 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |